Double egress series se1 or se2.
Double egress door.
It can comprise either a single door or a pair of doors where one is considered as the active door.
These openings are installed in cross corrid.
The de series double egress frames meet all the design parameters of conventional fe series double egress frames and is specified when cross corridor openings have the additional requirements of maximized clear opening width.
A double egress door system has two doors that swing in opposite directions from each other one side for people going out and one side for people going in.
A double egress frame is a double door frame prepared to receive two single acting doors swinging in opposite directions both doors are the same hand.
You need to login or register to bookmark favorite this content.
Double egress pairs may also be called rh rh the normal swing or lh lh the abnormal swing.
16 gauge steel cold rolled fire rated up to 3 hours.
Door mounts in center of frame.
The egress door leaking from the vestibule is a standard 36 door.
If you need a refresher on door handing here s a video and a handy dandy graphic.
The unique design of the de series frame allows for the use of swing clear hinges.
1 3 8 face frame 2 face optional.
What is the rule if i have double doors leading out of a manufacturing facility into a corridor then at the end of the corridor there is an additional set of double doors that leads to a vestibule.
Opening each door is possible by pushing the acting leaf side almost always the right hand side.
Double egress doors differ from double acting doors both in application and purpose.
Depth 5 1 4 14 fire label.
16 14 gauge.
Are the two sets of double doors corridor and vestibule.
What is the definition of double egress.
Up to 3 hours ul10b and ul10c underwriters laboratories applied only warnock hersey applied only series se step 2 shown.
Egress door sizing an egress door must be between 32 inches and 48 inches in width as measured between the face of the fully opened door 90 degrees and the stop on the door frame for double doors this measurement is from the face of the door to the edge of the other door leaf or mullion.
Our flush exit device on 7 8 pairs or double egress doors creates a 44 opening clearance per door.
By lori greene.
A double egress hollow metal frame is for a pair of doors in which the doors can only swing in the opposite direction.
Suitable for pairs or single doors exterior or interior the syntegra door systems robust mechanisms and electrical functions are designed to operate in the most demanding applications.